> diff --git a/Documentation/devicetree/bindings/misc/fsl,mma8653fc.txt b/Documentation/devicetree/bindings/misc/fsl,mma8653fc.txt > new file mode 100644 > index 0000000..3921acb > --- /dev/null > +++ b/Documentation/devicetree/bindings/misc/fsl,mma8653fc.txt > @@ -0,0 +1,96 @@ > +Freescale MMA8653FC 3-axis Accelerometer > + > +Required properties: > +- compatible > + "fsl,mma8653fc" > +- reg > + I2C address > + > +Optional properties: > + > +- interrupt-parent > + a phandle for the interrupt controller (see > + Documentation/devicetree/bindings/interrupt-controller/interrupts.txt) > +- interrupts > + interrupt line to which the chip is connected > +- int1 > + set to use interrupt line 1 instead of 2 If you have two interrupt output lines, you should have two entries in interrupts. You can use interrupt-names to determine which line(s) are wired up. I don't believe that you need this property. > +- int_active_high > + set interrupt line active high s/_/-/ in property names please. What happens if this isn't set? Is it active-low, or edge-triggered? It feels like we should be able to query when we need to set this from the IRQ(s). > +- ir_freefall_motion_x > + activate freefall/motion interrupts on x axis > +- ir_freefall_motion_y > + activate freefall/motion interrupts on y axis > +- ir_freefall_motion_z > + activate freefall/motion interrupts on z axis > +- irq_threshold > + 0 < value < 8000: threshold for motion interrupts in mg > +- ir_landscape_portrait > + activate landscape/portrait interrupts > +- ir_data_ready: > + activate data-ready interrupts > + Interrupt events can be activated in any combination. These all sounds like they would be better as runtime options. I don't see why these should necessarily be in the DT. > +- range > + 2, 4, or 8: range in g, default: 2 Likewise. It would be nice to have a better qualified name than "range". > +- auto_wake_sleep > + auto sleep mode (lower frequency) > +- motion_mode > + use motion mode instead of freefall mode (trigger if >threshold). > + per default an interrupt occurs if motion values fall below the > + value set in "threshold" and therefore can detect free fall on the > + vertical axis (depending on the position of the device). > + Setting this values inverts the behaviour and an interrupt occurs > + above the threshold value, so usually activate horizontal axis in > + this case. These both sound like they would be better as runtime options. > + > +- x-offset > + 0 < value < 500: calibration offset in mg > + this value has an offset of 250 itself: > + 0 is -250mg, 250 is 0 mg, 500 is 250mg > +- y-offset > + see x-offset > +- z-offset > + see x-offset I'm unsure about these; it really depends on what the calibration is for. Mark. -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html