On Wed, Sep 11, 2024 at 12:43:27PM +0200, AngeloGioacchino Del Regno wrote: > There is no reason to make specifying the clock-names property > mandatory, as the Global Command Engine HW needs only one clock. Have you checked to make sure that there are no users that do the lookup by name? > > Signed-off-by: AngeloGioacchino Del Regno <angelogioacchino.delregno@xxxxxxxxxxxxx> > --- > .../bindings/mailbox/mediatek,gce-mailbox.yaml | 11 ----------- > 1 file changed, 11 deletions(-) > > diff --git a/Documentation/devicetree/bindings/mailbox/mediatek,gce-mailbox.yaml b/Documentation/devicetree/bindings/mailbox/mediatek,gce-mailbox.yaml > index cef9d7601398..ff5d010fbcf0 100644 > --- a/Documentation/devicetree/bindings/mailbox/mediatek,gce-mailbox.yaml > +++ b/Documentation/devicetree/bindings/mailbox/mediatek,gce-mailbox.yaml > @@ -56,17 +56,6 @@ required: > - interrupts > - clocks > > -allOf: > - - if: > - not: > - properties: > - compatible: > - contains: > - const: mediatek,mt8195-gce > - then: > - required: > - - clock-names > - > additionalProperties: false > > examples: > -- > 2.46.0 >