L10A, being a fixed regulator, should have min_voltage = max_voltage, otherwise fixed rulator fails to probe. Fix the max_voltage range to be equal to minimum. Fixes: 4edbcf264fe2 ("arm64: dts: qcom: sda660-ifc6560: document missing USB PHY supplies") Signed-off-by: Dmitry Baryshkov <dmitry.baryshkov@xxxxxxxxxx> --- arch/arm64/boot/dts/qcom/sda660-inforce-ifc6560.dts | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/arch/arm64/boot/dts/qcom/sda660-inforce-ifc6560.dts b/arch/arm64/boot/dts/qcom/sda660-inforce-ifc6560.dts index ac0197624c09..09bc010ce56a 100644 --- a/arch/arm64/boot/dts/qcom/sda660-inforce-ifc6560.dts +++ b/arch/arm64/boot/dts/qcom/sda660-inforce-ifc6560.dts @@ -104,7 +104,7 @@ vreg_l10a_1p8: vreg-l10a-regulator { compatible = "regulator-fixed"; regulator-name = "vreg_l10a_1p8"; regulator-min-microvolt = <1804000>; - regulator-max-microvolt = <1896000>; + regulator-max-microvolt = <1804000>; regulator-always-on; regulator-boot-on; }; -- 2.39.2