On Sat, Sep 7, 2024 at 5:51 PM Jonathan Cameron <jic23@xxxxxxxxxx> wrote: > > On Sat, 7 Sep 2024 09:50:34 +0300 > Alexandru Ardelean <aardelean@xxxxxxxxxxxx> wrote: > > > From: Guillaume Stols <gstols@xxxxxxxxxxxx> > > > > The current implementation attempts to recover from an eventual glitch > > in the clock by checking frstdata state after reading the first > > channel's sample: If frstdata is low, it will reset the chip and > > return -EIO. > > > > This will only work in parallel mode, where frstdata pin is set low > > after the 2nd sample read starts. > > > > For the serial mode, according to the datasheet, "The FRSTDATA output > > returns to a logic low following the 16th SCLK falling edge.", thus > > after the Xth pulse, X being the number of bits in a sample, the check > > will always be true, and the driver will not work at all in serial > > mode if frstdata(optional) is defined in the devicetree as it will > > reset the chip, and return -EIO every time read_sample is called. > > > > Hence, this check must be removed for serial mode. > > > > Fixes: b9618c0cacd7 ("staging: IIO: ADC: New driver for AD7606/AD7606-6/AD7606-4") > > Signed-off-by: Guillaume Stols <gstols@xxxxxxxxxxxx> > > Reviewed-by: Nuno Sa <nuno.sa@xxxxxxxxxx> > > Link: https://patch.msgid.link/20240702-cleanup-ad7606-v3-1-18d5ea18770e@xxxxxxxxxxxx > > Cc: <Stable@xxxxxxxxxxxxxxx> > > Signed-off-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx> > Reference the fix patch in your cover letter, but don't include it in the series. > > I'll just get confused when I pick this up. ack will do