This value was verified by comparing register dumps of the MAX77693 charger with on mainline with a downstream kernel under Android; the value on downstream was set to 1.8 amps when charging with a proper charger. Add it to a new battery node and pass it to the MAX77693 charger so that the fast charge current setting can be used for charging. Tested-by: Henrik Grimler <henrik@xxxxxxxxxx> Signed-off-by: Artur Weber <aweber.kernel@xxxxxxxxx> --- Changes in v2: - Switched to monitored-battery --- arch/arm/boot/dts/samsung/exynos4212-tab3.dtsi | 6 ++++++ 1 file changed, 6 insertions(+) diff --git a/arch/arm/boot/dts/samsung/exynos4212-tab3.dtsi b/arch/arm/boot/dts/samsung/exynos4212-tab3.dtsi index 9bc05961577d..3c905bfedd96 100644 --- a/arch/arm/boot/dts/samsung/exynos4212-tab3.dtsi +++ b/arch/arm/boot/dts/samsung/exynos4212-tab3.dtsi @@ -159,6 +159,7 @@ charger_reg: CHARGER { charger { compatible = "maxim,max77693-charger"; + monitored-battery = <&battery>; maxim,constant-microvolt = <4350000>; maxim,min-system-microvolt = <3600000>; @@ -300,6 +301,11 @@ submic_bias_reg: voltage-regulator-5 { regulator-max-microvolt = <2800000>; }; + battery: battery { + compatible = "simple-battery"; + constant-charge-current-max-microamp = <1800000>; + }; + sound: sound { compatible = "samsung,midas-audio"; model = "TAB3"; -- 2.46.0