On Thu, 11 Jul 2024 23:15:55 +0200 Vasileios Amoiridis <vassilisamir@xxxxxxxxx> wrote: > This commit adds forced mode support in sensors BMP28x, BME28x, BMP3xx > and BMP58x. Sensors BMP18x and BMP085 are old and do not support this > feature so their operation is not affected at all. > > Essentially, up to now, the rest of the sensors were used in normal mode > all the time. This means that they are continuously doing measurements > even though these measurements are not used. Even though the sensor does > provide PM support, to cover all the possible use cases, the sensor needs > to go into sleep mode and wake up whenever necessary. > > This commit, adds sleep and forced mode support. Essentially, the sensor > sleeps all the time except for when a measurement is requested. When there > is a request for a measurement, the sensor is put into forced mode, starts > the measurement and after it is done we read the output and we put it again > in sleep mode. > > For really fast and more deterministic measurements, the triggered buffer > interface can be used, since the sensor is still used in normal mode for > that use case. > > This commit does not add though support for DEEP STANDBY, Low Power NORMAL > and CONTINUOUS modes, supported only by the BMP58x version. > > Signed-off-by: Vasileios Amoiridis <vassilisamir@xxxxxxxxx> Various minor comments inline. Thanks, Jonathan > --- > drivers/iio/pressure/bmp280-core.c | 276 +++++++++++++++++++++++++++-- > drivers/iio/pressure/bmp280.h | 12 ++ > 2 files changed, 269 insertions(+), 19 deletions(-) > > diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c > index 9c99373d66ec..fc8d42880eb8 100644 > --- a/drivers/iio/pressure/bmp280-core.c > +++ b/drivers/iio/pressure/bmp280-core.c > @@ -145,6 +145,12 @@ enum bmp280_scan { > BME280_HUMID, > }; > } > > +static int bmp280_set_mode(struct bmp280_data *data, u8 mode) > +{ > + int ret; > + > + switch (mode) { > + case BMP280_SLEEP: > + ret = regmap_write_bits(data->regmap, BMP280_REG_CTRL_MEAS, > + BMP280_MODE_MASK, BMP280_MODE_SLEEP); Use a local variable for the BMP280_MODE_* and then have the regmap_write_bits() after the switch statement. Could even make it a const data look up given you are getting a value based on the enum. > + break; > + case BMP280_FORCED: > + ret = regmap_write_bits(data->regmap, BMP280_REG_CTRL_MEAS, > + BMP280_MODE_MASK, BMP280_MODE_FORCED); > + break; > + case BMP280_NORMAL: > + ret = regmap_write_bits(data->regmap, BMP280_REG_CTRL_MEAS, > + BMP280_MODE_MASK, BMP280_MODE_NORMAL); > + break; > + default: > + return -EINVAL; > + } > + > + if (ret) { > + dev_err(data->dev, "failed to write ctrl_meas register\n"); > + return ret; > + } > + > + return 0; > +} > + > +static int bmp280_wait_conv(struct bmp280_data *data) > +{ > + unsigned int reg; > + int ret, meas_time; > + > + meas_time = BMP280_MEAS_OFFSET; > + > + if (data->oversampling_humid) > + meas_time += (1 << data->oversampling_humid) * BMP280_MEAS_DUR + > + BMP280_PRESS_HUMID_MEAS_OFFSET; Add a comment on why, if oversampling_humid is not set we end up with no time for measuring humidity. The MEAS_OFFSET is less than one MEAS_DUR so not it's not a case of that already incorporating the time. > + > + /* Pressure measurement time */ > + meas_time += (1 << data->oversampling_press) * BMP280_MEAS_DUR + > + BMP280_PRESS_HUMID_MEAS_OFFSET; > + > + /* Temperature measurement time */ > + meas_time += (1 << data->oversampling_temp) * BMP280_MEAS_DUR; > + > + usleep_range(meas_time, meas_time * 12 / 10); > + > + ret = regmap_read(data->regmap, BMP280_REG_STATUS, ®); > + if (ret) { > + dev_err(data->dev, "failed to read status register\n"); > + return ret; > + } > + if (reg & BMP280_REG_STATUS_MEAS_BIT) { > + dev_err(data->dev, "Measurement cycle didn't complete\n"); > + return -EBUSY; > + } > + > + return 0; > +} > + > static int bmp280_chip_config(struct bmp280_data *data) > { > u8 osrs = FIELD_PREP(BMP280_OSRS_TEMP_MASK, data->oversampling_temp + 1) | > @@ -994,7 +1078,7 @@ static int bmp280_chip_config(struct bmp280_data *data) > BMP280_OSRS_TEMP_MASK | > BMP280_OSRS_PRESS_MASK | > BMP280_MODE_MASK, > - osrs | BMP280_MODE_NORMAL); > + osrs | BMP280_MODE_SLEEP); > if (ret) { > dev_err(data->dev, "failed to write ctrl_meas register\n"); > return ret; > @@ -1100,6 +1184,8 @@ const struct bmp280_chip_info bmp280_chip_info = { > .read_temp = bmp280_read_temp, > .read_press = bmp280_read_press, > .read_calib = bmp280_read_calib, > + .set_mode = bmp280_set_mode, > + .wait_conv = bmp280_wait_conv, > .preinit = bmp280_preinit, > > .trigger_handler = bmp280_trigger_handler, > @@ -1218,6 +1304,8 @@ const struct bmp280_chip_info bme280_chip_info = { > .read_press = bmp280_read_press, > .read_humid = bme280_read_humid, > .read_calib = bme280_read_calib, > + .set_mode = bmp280_set_mode, > + .wait_conv = bmp280_wait_conv, > .preinit = bmp280_preinit, > > .trigger_handler = bme280_trigger_handler, > @@ -1505,6 +1593,75 @@ static int bmp380_preinit(struct bmp280_data *data) > return bmp380_cmd(data, BMP380_CMD_SOFT_RESET); > } > > +static int bmp380_set_mode(struct bmp280_data *data, u8 mode) > +{ > + int ret; > + > + switch (mode) { > + case BMP280_SLEEP: > + ret = regmap_write_bits(data->regmap, BMP380_REG_POWER_CONTROL, > + BMP380_MODE_MASK, > + FIELD_PREP(BMP380_MODE_MASK, > + BMP380_MODE_SLEEP)); As above. I'd use a local variable to stash the MODE* that you are going to write or just look it up in a const array. > + break; > + case BMP280_FORCED: > + ret = regmap_write_bits(data->regmap, BMP380_REG_POWER_CONTROL, > + BMP380_MODE_MASK, > + FIELD_PREP(BMP380_MODE_MASK, > + BMP380_MODE_FORCED)); > + break; > + case BMP280_NORMAL: > + ret = regmap_write_bits(data->regmap, BMP380_REG_POWER_CONTROL, > + BMP380_MODE_MASK, > + FIELD_PREP(BMP380_MODE_MASK, > + BMP380_MODE_NORMAL)); > + break; > + default: > + return -EINVAL; > + } > + > + if (ret) { > + dev_err(data->dev, "failed to write power control register\n"); > + return ret; > + } > + > + return 0; > +} > + > +static int bmp380_wait_conv(struct bmp280_data *data) > +{ > + unsigned int reg; > + int ret, meas_time; > + > + /* Offset measurement time */ > + meas_time = BMP380_MEAS_OFFSET; > + > + /* Pressure measurement time */ > + meas_time += (1 << data->oversampling_press) * BMP380_MEAS_DUR + > + BMP380_PRESS_MEAS_OFFSET; > + > + /* Temperature measurement time */ > + meas_time += (1 << data->oversampling_temp) * BMP380_MEAS_DUR + > + BMP380_TEMP_MEAS_OFFSET; > + > + usleep_range(meas_time, meas_time * 12 / 10); > + > + ret = regmap_read(data->regmap, BMP380_REG_STATUS, ®); > + if (ret) { > + dev_err(data->dev, "failed to read status register\n"); > + return ret; > + } > + > + if (!(reg & BMP380_STATUS_DRDY_PRESS_MASK) || > + !(reg & BMP380_STATUS_DRDY_TEMP_MASK)) { > + pr_info("Meas_time: %d\n", meas_time); Why as pr_info? Seems like part of the dev_err. > + dev_err(data->dev, "Measurement cycle didn't complete\n"); > + return -EBUSY; > + } > + > + return 0; > +} > + > static int bmp380_chip_config(struct bmp280_data *data) > { > bool change = false, aux; > @@ -1565,17 +1722,15 @@ static int bmp380_chip_config(struct bmp280_data *data) > * Resets sensor measurement loop toggling between sleep and > * normal operating modes. > */ > - ret = regmap_write_bits(data->regmap, BMP380_REG_POWER_CONTROL, > - BMP380_MODE_MASK, > - FIELD_PREP(BMP380_MODE_MASK, BMP380_MODE_SLEEP)); > + ret = bmp380_set_mode(data, BMP280_SLEEP); > if (ret) { > dev_err(data->dev, "failed to set sleep mode\n"); > return ret; > } > - usleep_range(2000, 2500); > - ret = regmap_write_bits(data->regmap, BMP380_REG_POWER_CONTROL, > - BMP380_MODE_MASK, > - FIELD_PREP(BMP380_MODE_MASK, BMP380_MODE_NORMAL)); > + > + usleep_range(data->start_up_time, data->start_up_time + 500); > + > + ret = bmp380_set_mode(data, BMP280_NORMAL); > if (ret) { > dev_err(data->dev, "failed to set normal mode\n"); > return ret; > @@ -1601,6 +1756,17 @@ static int bmp380_chip_config(struct bmp280_data *data) > } > } > > + /* Dummy read to empty data registers. */ > + ret = bmp380_read_press(data, &tmp); > + if (ret) > + return ret; > + > + ret = bmp380_set_mode(data, BMP280_SLEEP); > + if (ret) { > + dev_err(data->dev, "failed to set sleep mode\n"); > + return ret; > + } > + > return 0; > } > > @@ -1693,6 +1859,8 @@ const struct bmp280_chip_info bmp380_chip_info = { > .read_temp = bmp380_read_temp, > .read_press = bmp380_read_press, > .read_calib = bmp380_read_calib, > + .set_mode = bmp380_set_mode, > + .wait_conv = bmp380_wait_conv, > .preinit = bmp380_preinit, > > .trigger_handler = bmp380_trigger_handler, > @@ -2080,6 +2248,65 @@ static int bmp580_preinit(struct bmp280_data *data) > return PTR_ERR_OR_ZERO(devm_nvmem_register(config.dev, &config)); > } > > +static int bmp580_set_mode(struct bmp280_data *data, u8 mode) > +{ > + int ret; > + > + switch (mode) { > + case BMP280_SLEEP: > + ret = regmap_write_bits(data->regmap, BMP580_REG_ODR_CONFIG, > + BMP580_MODE_MASK, > + FIELD_PREP(BMP580_MODE_MASK, > + BMP580_MODE_SLEEP)); > + break; > + case BMP280_FORCED: > + ret = regmap_set_bits(data->regmap, BMP580_REG_DSP_CONFIG, > + BMP580_DSP_IIR_FORCED_FLUSH); > + check that ret. > + ret = regmap_write_bits(data->regmap, BMP580_REG_ODR_CONFIG, > + BMP580_MODE_MASK, > + FIELD_PREP(BMP580_MODE_MASK, > + BMP580_MODE_FORCED)); This one is more complex so a switch statement makes sense here. > + break; > + case BMP280_NORMAL: > + ret = regmap_write_bits(data->regmap, BMP580_REG_ODR_CONFIG, > + BMP580_MODE_MASK, > + FIELD_PREP(BMP580_MODE_MASK, > + BMP580_MODE_NORMAL)); > + break; > + default: > + return -EINVAL; > + } > + > + if (ret) { > + dev_err(data->dev, "failed to write power control register\n"); > + return ret; > + } > + > + return 0; > +} > + > +static int bmp580_wait_conv(struct bmp280_data *data) > +{ > + /* > + * Taken from datasheet, Section 2 "Specification, Table 3 "Electrical > + * characteristics > + */ > + const int time_conv_press[] = { 0, 1050, 1785, 3045, 5670, 10920, 21420, > + 42420, 84420}; > + const int time_conv_temp[] = { 0, 1050, 1105, 1575, 2205, 3465, 6090, > + 11340, 21840}; > + int meas_time; > + > + meas_time = 4000 + time_conv_temp[data->oversampling_temp] + > + time_conv_press[data->oversampling_press]; > + > + usleep_range(meas_time, meas_time * 12 / 10); > + > + return 0; > +} > + one blank line only. > + > static int bmp580_chip_config(struct bmp280_data *data) > { > bool change = false, aux; > @@ -2150,17 +2377,6 @@ static int bmp580_chip_config(struct bmp280_data *data) > return ret; > } > > - /* Restore sensor to normal operation mode */ > - ret = regmap_write_bits(data->regmap, BMP580_REG_ODR_CONFIG, > - BMP580_MODE_MASK, > - FIELD_PREP(BMP580_MODE_MASK, BMP580_MODE_NORMAL)); > - if (ret) { > - dev_err(data->dev, "failed to set normal mode\n"); > - return ret; > - } > - /* From datasheet's table 4: electrical characteristics */ > - usleep_range(3000, 3500); > - > if (change) { > /* > * Check if ODR and OSR settings are valid or we are > @@ -2256,6 +2472,8 @@ const struct bmp280_chip_info bmp580_chip_info = { > .chip_config = bmp580_chip_config, > .read_temp = bmp580_read_temp, > .read_press = bmp580_read_press, > + .set_mode = bmp580_set_mode, > + .wait_conv = bmp580_wait_conv, > .preinit = bmp580_preinit, > > .trigger_handler = bmp580_trigger_handler, > @@ -2503,6 +2721,16 @@ static int bmp180_read_press(struct bmp280_data *data, u32 *comp_press) > return 0; > } > > +static int bmp180_set_mode(struct bmp280_data *data, u8 mode) > +{ > + return 0; Add a comment on why these are stubs. It's in the patch description, but better to have it recorded in the code. > +} > + > +static int bmp180_wait_conv(struct bmp280_data *data) > +{ > + return 0; > +} > + >