Hi Paul, On 6/18/24 07:59, Paul Menzel wrote: [ ... ]
I did $ tail -3 /etc/sensors3.conf chip "spd5118-*" set temp1_max 56000 set temp1_crit 84000 but it stays with the defaults: ``` $ sensors spd5118-i2c-0-53 Adapter: SMBus I801 adapter at efa0 temp1: +20.8°C (low = +0.0°C, high = +55.0°C) (crit low = +0.0°C, crit = +85.0°C)
You'd have to write directly into the attribute files. For example, if you have $ grep . /sys/class/hwmon/*/name /sys/class/hwmon/hwmon0/name:nvme /sys/class/hwmon/hwmon1/name:nct6687 /sys/class/hwmon/hwmon2/name:k10temp /sys/class/hwmon/hwmon3/name:spd5118 /sys/class/hwmon/hwmon4/name:spd5118 /sys/class/hwmon/hwmon5/name:spd5118 /sys/class/hwmon/hwmon6/name:spd5118 /sys/class/hwmon/hwmon7/name:mt7921_phy0 /sys/class/hwmon/hwmon8/name:amdgpu you could run sudo bash -c 'echo 56000 > /sys/class/hwmon/hwmon3/temp1_max' Thanks, Guenter