On 02/26/2015 05:59 AM, Lukasz Majewski wrote:
The PWM FAN device can now be used as a thermal cooling device. Necessary infrastructure has been added in this commit. Signed-off-by: Lukasz Majewski <l.majewski@xxxxxxxxxxx> Acked-by: Eduardo Valentin <edubezval@xxxxxxxxx> --- Changes for v2: - Replace pwm_fan_cooling_states with pwm_fan_cooling_levels - Update ctx->pwm_fan_state when correct data from device tree is available - Using therma_cdev_update() when thermal is ready for controlling the fan Changes for v3: - Rename patch heading - pwm_fan_of_get_cooling_data() now returns -EINVAL when no "cooling-levels" property defined - register of cooling device only when proper cooling data is present Changes for v4: - None Changes for v5: - Check for IS_ENABLED(CONFIG_THERMAL) has been added to prevent from executing thermal_* specific functions Changes for v6: - Adding missing ctx == NULL check in pwm_fan_get_max_state() - Call to thermal_cooling_device_unregister(ctx->cdev); at pwm_fan_remove() - struct thermal_cooling_device *cdev; added to struct pwm_fan_ctx --- drivers/hwmon/pwm-fan.c | 89 ++++++++++++++++++++++++++++++++++++++++++++++++- 1 file changed, 88 insertions(+), 1 deletion(-)
[ ... ]
@@ -200,6 +286,7 @@ static int pwm_fan_remove(struct platform_device *pdev) { struct pwm_fan_ctx *ctx = platform_get_drvdata(pdev); + thermal_cooling_device_unregister(ctx->cdev);
Unfortunately there is still no prototype for this if CONFIG_THERMAL is not configured. Two options: Yet another revision, or wait a week until the prototypes are (hopefully) available and submit a patch without the conditionals. Guenter -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html