Reorder the attributes of the sysc node so that the ralink prefixed attribute is placed after those which lack prefixes. Signed-off-by: Justin Swartz <justin.swartz@xxxxxxxxxxxxxxxx> --- arch/mips/boot/dts/ralink/mt7621.dtsi | 5 ++++- 1 file changed, 4 insertions(+), 1 deletion(-) diff --git a/arch/mips/boot/dts/ralink/mt7621.dtsi b/arch/mips/boot/dts/ralink/mt7621.dtsi index 696460b2d..d1d4399d7 100644 --- a/arch/mips/boot/dts/ralink/mt7621.dtsi +++ b/arch/mips/boot/dts/ralink/mt7621.dtsi @@ -68,12 +68,15 @@ palmbus: palmbus@1e000000 { sysc: syscon@0 { compatible = "mediatek,mt7621-sysc", "syscon"; reg = <0x0 0x100>; + #clock-cells = <1>; #reset-cells = <1>; - ralink,memctl = <&memc>; + clock-output-names = "xtal", "cpu", "bus", "50m", "125m", "150m", "250m", "270m"; + + ralink,memctl = <&memc>; }; wdt: watchdog@100 { --