On 05/03/2024 08:18, Peng Fan wrote: >> Subject: Re: [PATCH v3 1/2] dt-bindindgs: clock: support NXP i.MX95 BLK CTL >> module >> >> On 05/03/2024 05:13, Peng Fan wrote: >>>>> + >>>>> +examples: >>>>> + # Clock Control Module node: >>>>> + - | >>>>> + #include <dt-bindings/clock/nxp,imx95-clock.h> >>>>> + >>>>> + syscon@4c410000 { >>>> >>>> clock-controller@... >>> >>> But this is a syscon, using clock-controller will trigger dt check >>> warning. >> >> Which warning? > > I just recalled that node with syscon in compatible string needs > has syscon as node, I maybe wrong. Just paste the warning, so we can think about it. > >> >>>> >>>> As that is the main feature/function. >>>> >>>>> + compatible = "nxp,imx95-vpumix-csr", "syscon"; >>>>> + reg = <0x4c410000 0x10000>; >>>>> + #clock-cells = <1>; >>>> >>>> Please make the example as full as possible. For example, add >>>> mux-controller node. Do some of the blocks not have mux ctrl? >>> >>> Yes. The blk ctrl is not just for clock, some registers has mux ctrl, >>> such as Pixel_link_sel. >> >> Then mux-controller should not be allowed for them. > > You mean I should not add mux-controller under the blk ctrl node? mux-controller is already there, isn't it? I am saying your binding is not precise. Your binding implies that ALL OF THEM have mux controller. You told me it is not true, so you have change the meaning of binding and disallow the mux-controller for the cases it is not applicable. Best regards, Krzysztof