Re: [PATCH v3 13/15] clk: samsung: Implement manual PLL control for ARM64 SoCs

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Sun, Feb 25, 2024 at 10:09 AM Krzysztof Kozlowski
<krzysztof.kozlowski@xxxxxxxxxx> wrote:
>
> On 24/02/2024 21:20, Sam Protsenko wrote:
> > Some ARM64 Exynos chips are capable to control PLL clocks automatically.
> > For those chips, whether the PLL is controlled automatically or manually
> > is chosen in PLL_CON1 register with next bits:
> >
> >     [28]  ENABLE_AUTOMATIC_CLKGATING
> >     [1]   MANUAL_PLL_CTRL
> >     [0]   AUTO_PLL_CTRL
> >
> > The bl2 bootloader sets 0x10000001 value for some PLL_CON1 registers,
> > which means any attempt to control those PLLs manually (e.g.
> > disabling/enabling those PLLs or changing MUX parent clocks) would lead
> > to PLL lock timeout with error message like this:
> >
> >     Could not lock PLL ...
> >
> > At the moment, all Samsung clock drivers implement manual clock control.
> > So in order to make it possible to control PLLs, corresponding PLL_CON1
> > registers should be set to 0x2 first.
> >
> > Some older ARM64 chips don't implement the automatic clock control
> > though. It also might be desirable to configure some PLLs for manual
> > control, while keeping the default configuration for the rest. So it'd
> > convenient to choose this PLL mode for each CMU separately. Introduce
> > .manual_plls field to CMU structure to choose the PLL control mode.
> > Because it'll be initialized with "false" in all existing CMU
> > structures by default, it won't affect any existing clock drivers,
> > allowing for this feature to be enabled gradually when it's needed with
> > no change for the rest of users. In case .manual_plls is set, set
> > PLL_CON1 registers to manual control, akin to what's already done for
> > gate clocks in exynos_arm64_init_clocks(). Of course, PLL_CON1 registers
> > should be added to corresponding struct samsung_cmu_info::clk_regs array
> > to make sure they get initialized.
> >
> > No functional change. This patch adds a feature, but doesn't enable it
> > for any users.
> >
> > Signed-off-by: Sam Protsenko <semen.protsenko@xxxxxxxxxx>
> > ---
> > Changes in v3:
> >   - none
> >
> > Changes in v2:
> >   - none
> >
> >  drivers/clk/samsung/clk-exynos-arm64.c | 44 +++++++++++++++++---------
> >  drivers/clk/samsung/clk.h              |  4 +++
> >  2 files changed, 33 insertions(+), 15 deletions(-)
> >
> > diff --git a/drivers/clk/samsung/clk-exynos-arm64.c b/drivers/clk/samsung/clk-exynos-arm64.c
> > index 6fb7194df7ab..55490209b9a9 100644
> > --- a/drivers/clk/samsung/clk-exynos-arm64.c
> > +++ b/drivers/clk/samsung/clk-exynos-arm64.c
> > @@ -25,6 +25,19 @@
> >  #define GATE_OFF_START               0x2000
> >  #define GATE_OFF_END         0x2fff
> >
> > +/* PLL CON register offsets range */
> > +#define PLL_CON_START                0x100
> > +#define PLL_CON_END          0x600
> > +
> > +/* PLL register bits */
> > +#define PLL_CON1_MANUAL              BIT(1)
> > +
> > +/* Helper macros to check for particular clock regiter by its offset */
> > +#define IS_GATE_REG(o)               ((o) >= GATE_OFF_START && (o) <= GATE_OFF_END)
> > +#define IS_PLL_CONx_REG(o)   ((o) >= PLL_CON_START && (o) <= PLL_CON_END)
> > +#define IS_PLL_CON1_REG(o)   \
> > +     (IS_PLL_CONx_REG(o) && ((o) & 0xf) == 0x4 && !((o) & 0x10))
>
> These should be static functions, because it leads to trickier code. See
> also checkpatch warning.
>

For my taste macros are more compact in this particular case. But I
don't mind, will send out the reworked patches soon.

> Best regards,
> Krzysztof
>