Hello Alexey,
On 2024-01-26 00:13, Dragan Simic wrote:
On 2024-01-24 21:30, Alexey Charkov wrote:
This enables thermal monitoring on Radxa Rock 5B and links the PWM
fan as an active cooling device managed automatically by the thermal
subsystem, with a target SoC temperature of 55C
Signed-off-by: Alexey Charkov <alchark@xxxxxxxxx>
---
arch/arm64/boot/dts/rockchip/rk3588-rock-5b.dts | 25
++++++++++++++++++++++++-
1 file changed, 24 insertions(+), 1 deletion(-)
diff --git a/arch/arm64/boot/dts/rockchip/rk3588-rock-5b.dts
b/arch/arm64/boot/dts/rockchip/rk3588-rock-5b.dts
index 9b7bf6cec8bd..c4c94e0b6163 100644
--- a/arch/arm64/boot/dts/rockchip/rk3588-rock-5b.dts
+++ b/arch/arm64/boot/dts/rockchip/rk3588-rock-5b.dts
@@ -52,7 +52,7 @@ led_rgb_b {
fan: pwm-fan {
compatible = "pwm-fan";
- cooling-levels = <0 95 145 195 255>;
+ cooling-levels = <0 120 150 180 210 240 255>;
fan-supply = <&vcc5v0_sys>;
pwms = <&pwm1 0 50000 0>;
#cooling-cells = <2>;
@@ -180,6 +180,25 @@ &cpu_l3 {
cpu-supply = <&vdd_cpu_lit_s0>;
};
+&package_thermal {
+ polling-delay = <1000>;
+
+ trips {
+ package_fan: package-fan {
+ temperature = <55000>;
+ hysteresis = <2000>;
+ type = "active";
+ };
+ };
+
+ cooling-maps {
+ map-fan {
+ trip = <&package_fan>;
+ cooling-device = <&fan THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
+ };
+ };
+};
It should be better to have two new trips and two new cooling maps
defined, instead of having just one trip/map pair, like this:
&package_thermal {
polling-delay = <1000>;
trips {
package_warm: package-warm {
temperature = <55000>;
hysteresis = <2000>;
type = "active";
};
package_hot: package-hot {
temperature = <65000>;
hysteresis = <2000>;
type = "active";
};
};
cooling-maps {
mapX {
trip = <&package_warm>;
cooling-device = <&fan THERMAL_NO_LIMIT 1>;
};
mapY {
trip = <&package_hot>;
cooling-device = <&fan 2 THERMAL_NO_LIMIT>;
};
};
};
The idea behind this approach is to keep the fan spinning at the lowest
available speed until the package temperature reaches the second trip's
temperature level, at which point the fan starts ramping up. An
approach
like this is already employed by the Pine64 RockPro64 SBC.
This way, we'll be doing our best to keep the fan noise down; of
course,
it will depend on the particular heatsink and fan combo how long the
fan
can be kept at the lowest speed, but we should aim at supporting as
many
different cooling setups as possible, and as well as possible, out of
the
box and with no additional tweaking required.
Please notice "mapX" and "mapY" as the names of the additional cooling
maps,
where X and Y are simply the next lowest available indices, which is
pretty
much the usual way to name the additional cooling maps.
Just checking, have you seen this? Quite a few messages were exchanged
on the same day, so just wanted to make sure you didn't miss this one.
&i2c0 {
pinctrl-names = "default";
pinctrl-0 = <&i2c0m2_xfer>;
@@ -738,6 +757,10 @@ regulator-state-mem {
};
};
+&tsadc {
+ status = "okay";
+};
+
&uart2 {
pinctrl-0 = <&uart2m0_xfer>;
status = "okay";