On 16/11/2023 14:24, Rafał Miłecki wrote:
From: Rafał Miłecki <rafal@xxxxxxxxxx> According to the "inside-secure,safexcel-eip97" binding "clock-names" is required only if there are two clocks specified. If present the first name must by "core". Name "infra_eip97_ck" is invalid and was probably just a typo. Drop it. Fixes: ecc5287cfe53 ("arm64: dts: mt7986: add crypto related device nodes") Cc: Sam Shih <sam.shih@xxxxxxxxxxxx> Signed-off-by: Rafał Miłecki <rafal@xxxxxxxxxx>
Applied, thanks.
--- arch/arm64/boot/dts/mediatek/mt7986a.dtsi | 1 - 1 file changed, 1 deletion(-) diff --git a/arch/arm64/boot/dts/mediatek/mt7986a.dtsi b/arch/arm64/boot/dts/mediatek/mt7986a.dtsi index 24eda00e320d..017168453ec5 100644 --- a/arch/arm64/boot/dts/mediatek/mt7986a.dtsi +++ b/arch/arm64/boot/dts/mediatek/mt7986a.dtsi @@ -234,7 +234,6 @@ crypto: crypto@10320000 { <GIC_SPI 119 IRQ_TYPE_LEVEL_HIGH>; interrupt-names = "ring0", "ring1", "ring2", "ring3"; clocks = <&infracfg CLK_INFRA_EIP97_CK>; - clock-names = "infra_eip97_ck"; assigned-clocks = <&topckgen CLK_TOP_EIP_B_SEL>; assigned-clock-parents = <&apmixedsys CLK_APMIXED_NET2PLL>; status = "disabled";