The example for rk809 picked up the wrong compatible string when the binding was converted to yaml. As a result it also specified too many vccX-supply properties. Fix typo in the example specifying wrong compatible string for rk809. Remove additional vccX-supply properties that dont exist on rk809 so that binding checks pass again. Signed-off-by: Tim Lunn <tim@xxxxxxxxxxxxxx> Acked-by: Conor Dooley <conor.dooley@xxxxxxxxxxxxx> Fixes: 6c38ca03406e ("dt-bindings: mfd: rk808: Convert bindings to yaml") --- Changes in v3: - Drop label from rk809 node Changes in v2: - Fix vcc-supply warning detected by dt_binding bot Documentation/devicetree/bindings/mfd/rockchip,rk809.yaml | 7 ++----- 1 file changed, 2 insertions(+), 5 deletions(-) diff --git a/Documentation/devicetree/bindings/mfd/rockchip,rk809.yaml b/Documentation/devicetree/bindings/mfd/rockchip,rk809.yaml index 839c0521f1e5..eb057607dc54 100644 --- a/Documentation/devicetree/bindings/mfd/rockchip,rk809.yaml +++ b/Documentation/devicetree/bindings/mfd/rockchip,rk809.yaml @@ -126,8 +126,8 @@ examples: #address-cells = <1>; #size-cells = <0>; - rk808: pmic@1b { - compatible = "rockchip,rk808"; + pmic@1b { + compatible = "rockchip,rk809"; reg = <0x1b>; #clock-cells = <1>; clock-output-names = "xin32k", "rk808-clkout2"; @@ -146,9 +146,6 @@ examples: vcc7-supply = <&vcc_sysin>; vcc8-supply = <&vcc3v3_sys>; vcc9-supply = <&vcc_sysin>; - vcc10-supply = <&vcc_sysin>; - vcc11-supply = <&vcc_sysin>; - vcc12-supply = <&vcc3v3_sys>; regulators { vdd_center: DCDC_REG1 { -- 2.40.1