On 24/12/2023 15:34, Petre Rodan wrote: > Add spi based example. > > Add spi-max-frequency property required by chip specifications. > > Add additional maintainer. > > Signed-off-by: Petre Rodan <petre.rodan@xxxxxxxxxxxxxxx> > Signed-off-by: Andreas Klinger <ak@xxxxxxxxxxxxx> > --- > .../iio/pressure/honeywell,mprls0025pa.yaml | 26 +++++++++++++++++-- > 1 file changed, 24 insertions(+), 2 deletions(-) > > diff --git a/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml b/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml > index e4021306d187..430496b047c7 100644 > --- a/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml > +++ b/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml > @@ -8,12 +8,12 @@ title: Honeywell mprls0025pa pressure sensor > > maintainers: > - Andreas Klinger <ak@xxxxxxxxxxxxx> > + - Petre Rodan <petre.rodan@xxxxxxxxxxxxxxx> > > description: | > Honeywell pressure sensor of model mprls0025pa. > > - This sensor has an I2C and SPI interface. Only the I2C interface is > - implemented. > + This sensor has an I2C and SPI interface. Both are supported. Instead drop that sentence. Current driver support should not matter for the bindings. > > There are many models with different pressure ranges available. The vendor > calls them "mpr series". All of them have the identical programming model and > @@ -88,6 +88,9 @@ properties: > Maximum pressure value the sensor can measure in pascal. > To be specified only if honeywell,pressure-triplet is not set. > > + spi-max-frequency: > + maximum: 800000 So you miss allOf: with $ref to spi props. Best regards, Krzysztof