On Tue, 5 Dec 2023 12:29:00 -0800, Sam Edwards wrote: > JEDEC standard JESD84-B51 defines the eMMC Data Strobe line, which is > currently used only in HS400 mode, as a device->host clock signal that > "is used only in read operation. The Data Strobe is always High-Z (not > driven by the device and pulled down by RDS) or Driven Low in write > operation, except during CRC status response." RDS is a pull-down > resistor specified in the 10K-100K ohm range. Thus per the standard, the > Data Strobe is always pulled to ground (by the eMMC and/or RDS) during > write operations. > > [...] Applied, thanks! [1/1] arm64: dts: rockchip: Fix eMMC Data Strobe PD commit: 37f3d6108730713c411827ab4af764909f4dfc78 Best regards, -- Heiko Stuebner <heiko@xxxxxxxxx>