On Thu, Nov 09, 2023 at 01:32:52PM +0100, Christian Marangi wrote: > From: Robert Marko <robimarko@xxxxxxxxx> > > Aquantia PHY-s require firmware to be loaded before they start operating. > It can be automatically loaded in case when there is a SPI-NOR connected > to Aquantia PHY-s or can be loaded from the host via MDIO. > > This patch adds support for loading the firmware via MDIO as in most cases > there is no SPI-NOR being used to save on cost. > Firmware loading code itself is ported from mainline U-boot with cleanups. > > The firmware has mixed values both in big and little endian. > PHY core itself is big-endian but it expects values to be in little-endian. > The firmware is little-endian but CRC-16 value for it is stored at the end > of firmware in big-endian. > > It seems the PHY does the conversion internally from firmware that is > little-endian to the PHY that is big-endian on using the mailbox > but mailbox returns a big-endian CRC-16 to verify the written data > integrity. > > Co-developed-by: Christian Marangi <ansuelsmth@xxxxxxxxx> > Signed-off-by: Robert Marko <robimarko@xxxxxxxxx> > Signed-off-by: Christian Marangi <ansuelsmth@xxxxxxxxx> Reviewed-by: Andrew Lunn <andrew@xxxxxxx> Andrew