On Thu, 19 Oct 2023 at 11:42, Varadarajan Narayanan <quic_varada@xxxxxxxxxxx> wrote: > > The set rate and determine rate operations are different between > Stromer and Stromer Plus PLLs. Since the programming sequence is > different, the PLLs dont get configured properly and random, > inexplicable crash/freeze is seen. Hence, use stromer plus ops > for ipq_pll_stromer_plus. > > Acked-by: Stephen Boyd <sboyd@xxxxxxxxxx> > Fixes: c7ef7fbb1ccf ("clk: qcom: apss-ipq-pll: add support for IPQ5332") > Signed-off-by: Kathiravan T <quic_kathirav@xxxxxxxxxxx> > Signed-off-by: Varadarajan Narayanan <quic_varada@xxxxxxxxxxx> > --- > v4: Update commit log to include > "What goes wrong if we don't have this patch?" > v2: Add Fixes tag > --- > drivers/clk/qcom/apss-ipq-pll.c | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@xxxxxxxxxx> -- With best wishes Dmitry