On Thu, Oct 12, 2023 at 01:55:36PM -0700, Stephen Boyd wrote: > Quoting Varadarajan Narayanan (2023-10-12 02:26:17) > > Stromer plus APSS PLL does not support dynamic frequency scaling. > > To switch between frequencies, we have to shut down the PLL, > > configure the L and ALPHA values and turn on again. So introduce the > > separate set of ops for Stromer Plus PLL. > > Does this assume the PLL is always on? Yes once the PLL is configured by apss-ipq-pll driver, it is always on. > > Signed-off-by: Kathiravan T <quic_kathirav@xxxxxxxxxxx> > > Signed-off-by: Varadarajan Narayanan <quic_varada@xxxxxxxxxxx> > > --- > > v2: Use clk_alpha_pll_stromer_determine_rate, instead of adding new > > clk_alpha_pll_stromer_plus_determine_rate as the alpha pll width > > is same for both > > > > Fix review comments > > udelay(50) -> usleep_range(50, 60) > > Remove SoC-specific from print message > > --- > > drivers/clk/qcom/clk-alpha-pll.c | 57 ++++++++++++++++++++++++++++++++++++++++ > > drivers/clk/qcom/clk-alpha-pll.h | 1 + > > 2 files changed, 58 insertions(+) > > > > diff --git a/drivers/clk/qcom/clk-alpha-pll.c b/drivers/clk/qcom/clk-alpha-pll.c > > index 4edbf77..5221b6c 100644 > > --- a/drivers/clk/qcom/clk-alpha-pll.c > > +++ b/drivers/clk/qcom/clk-alpha-pll.c > > @@ -2508,3 +2508,60 @@ const struct clk_ops clk_alpha_pll_stromer_ops = { > > .set_rate = clk_alpha_pll_stromer_set_rate, > > }; > > EXPORT_SYMBOL_GPL(clk_alpha_pll_stromer_ops); > > + > > +static int clk_alpha_pll_stromer_plus_set_rate(struct clk_hw *hw, > > + unsigned long rate, > > + unsigned long prate) > > +{ > > + struct clk_alpha_pll *pll = to_clk_alpha_pll(hw); > > + u32 l, alpha_width = pll_alpha_width(pll); > > + int ret; > > + u64 a; > > + > > + rate = alpha_pll_round_rate(rate, prate, &l, &a, alpha_width); > > + > > + regmap_write(pll->clkr.regmap, PLL_MODE(pll), 0); > > There's a theoretical problem here if I understand correctly. A call to > clk_enable() can happen while clk_set_rate() is in progress or vice > versa. Probably we need some sort of spinlock for this PLL that > synchronizes any enable/disable with the rate change so that when we > restore the enable bit the clk isn't enabled when it was supposed to be > off. Since the PLL is always on, should we worry about enable/disable? If you feel it is better to synchronize with a spin lock, will add and post a new revision. Please let me know. Thanks Varada