From: Fabio Estevam <festevam@xxxxxxx> Document the critical-action property to describe the thermal action the OS should perform after the critical temperature is reached. The possible values are "shutdown" and "reboot". The motivation for introducing the critical-action property is that different systems may need different thermal actions when the critical temperature is reached. For example, a desktop PC may want the OS to trigger a shutdown when the critical temperature is reached. However, in some embedded cases, such behavior does not suit well, as the board may be unattended in the field and rebooting may be a better approach. The bootloader may also benefit from this new property as it can check the SoC temperature and in case the temperature is above the critical point, it can trigger a shutdown or reboot accordingly. Signed-off-by: Fabio Estevam <festevam@xxxxxxx> Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx> --- Changes since v7: - Made critical-action a property of the top-level thermal-zone node. (Rafael) .../devicetree/bindings/thermal/thermal-zones.yaml | 8 ++++++++ 1 file changed, 8 insertions(+) diff --git a/Documentation/devicetree/bindings/thermal/thermal-zones.yaml b/Documentation/devicetree/bindings/thermal/thermal-zones.yaml index 4f3acdc4dec0..d28f3fe1045d 100644 --- a/Documentation/devicetree/bindings/thermal/thermal-zones.yaml +++ b/Documentation/devicetree/bindings/thermal/thermal-zones.yaml @@ -48,6 +48,14 @@ properties: platform-data regarding temperature thresholds and the mitigation actions to take when the temperature crosses those thresholds. + critical-action: + $ref: /schemas/types.yaml#/definitions/string + description: + The action the OS should perform after the critical temperature is reached. + enum: + - shutdown + - reboot + patternProperties: "^[a-zA-Z][a-zA-Z0-9\\-]{1,12}-thermal$": type: object -- 2.34.1