Fix the documentation issues pointed by Pavel while backporting it to 6.1.y-cip. - Replace '32- bit'->'32-bit' - Consistently remove '.' at the end of line for the specifications - Replace ' (excluding MTU8)'-> '(excluding MTU8)' Reported-by: Pavel Machek <pavel@xxxxxxx> Closes: https://patchwork.kernel.org/project/cip-dev/patch/20230606075235.183132-3-biju.das.jz@xxxxxxxxxxxxxx/ Signed-off-by: Biju Das <biju.das.jz@xxxxxxxxxxxxxx> Acked-by: Conor Dooley <conor.dooley@xxxxxxxxxxxxx> --- v1->v2: * Added Ack by Conor Dooley --- .../bindings/timer/renesas,rz-mtu3.yaml | 28 +++++++++---------- 1 file changed, 14 insertions(+), 14 deletions(-) diff --git a/Documentation/devicetree/bindings/timer/renesas,rz-mtu3.yaml b/Documentation/devicetree/bindings/timer/renesas,rz-mtu3.yaml index bffdab0b0185..eb2d5ebe4df0 100644 --- a/Documentation/devicetree/bindings/timer/renesas,rz-mtu3.yaml +++ b/Documentation/devicetree/bindings/timer/renesas,rz-mtu3.yaml @@ -11,8 +11,8 @@ maintainers: description: | This hardware block consists of eight 16-bit timer channels and one - 32- bit timer channel. It supports the following specifications: - - Pulse input/output: 28 lines max. + 32-bit timer channel. It supports the following specifications: + - Pulse input/output: 28 lines max - Pulse input 3 lines - Count clock 11 clocks for each channel (14 clocks for MTU0, 12 clocks for MTU2, and 10 clocks for MTU5, four clocks for MTU1-MTU2 combination @@ -23,11 +23,11 @@ description: | - Input capture function (noise filter setting available) - Counter-clearing operation - Simultaneous writing to multiple timer counters (TCNT) - (excluding MTU8). + (excluding MTU8) - Simultaneous clearing on compare match or input capture - (excluding MTU8). + (excluding MTU8) - Simultaneous input and output to registers in synchronization with - counter operations (excluding MTU8). + counter operations (excluding MTU8) - Up to 12-phase PWM output in combination with synchronous operation (excluding MTU8) - [MTU0 MTU3, MTU4, MTU6, MTU7, and MTU8] @@ -40,26 +40,26 @@ description: | - [MTU3, MTU4, MTU6, and MTU7] - Through interlocked operation of MTU3/4 and MTU6/7, the positive and negative signals in six phases (12 phases in total) can be output in - complementary PWM and reset-synchronized PWM operation. + complementary PWM and reset-synchronized PWM operation - In complementary PWM mode, values can be transferred from buffer registers to temporary registers at crests and troughs of the timer- counter values or when the buffer registers (TGRD registers in MTU4 - and MTU7) are written to. - - Double-buffering selectable in complementary PWM mode. + and MTU7) are written to + - Double-buffering selectable in complementary PWM mode - [MTU3 and MTU4] - Through interlocking with MTU0, a mode for driving AC synchronous motors (brushless DC motors) by using complementary PWM output and reset-synchronized PWM output is settable and allows the selection - of two types of waveform output (chopping or level). + of two types of waveform output (chopping or level) - [MTU5] - - Capable of operation as a dead-time compensation counter. + - Capable of operation as a dead-time compensation counter - [MTU0/MTU5, MTU1, MTU2, and MTU8] - 32-bit phase counting mode specifiable by combining MTU1 and MTU2 and - through interlocked operation with MTU0/MTU5 and MTU8. + through interlocked operation with MTU0/MTU5 and MTU8 - Interrupt-skipping function - In complementary PWM mode, interrupts on crests and troughs of counter values and triggers to start conversion by the A/D converter can be - skipped. + skipped - Interrupt sources: 43 sources. - Buffer operation: - Automatic transfer of register data (transfer from the buffer @@ -68,9 +68,9 @@ description: | - A/D converter start triggers can be generated - A/D converter start request delaying function enables A/D converter to be started with any desired timing and to be synchronized with - PWM output. + PWM output - Low power consumption function - - The MTU3a can be placed in the module-stop state. + - The MTU3a can be placed in the module-stop state There are two phase counting modes. 16-bit phase counting mode in which MTU1 and MTU2 operate independently, and cascade connection 32-bit phase -- 2.25.1