On Sun, Jun 11, 2023 at 10:53:56AM +0300, Maxim Kiselev wrote: > вс, 11 июн. 2023 г. в 01:14, Conor Dooley <conor@xxxxxxxxxx>: > > > > On Sat, Jun 10, 2023 at 11:31:03PM +0300, Maxim Kiselev wrote: > > > сб, 10 июн. 2023 г. в 21:01, Conor Dooley <conor@xxxxxxxxxx>: > > > > > > ... > > > > > > > > > > + - | > > > > > > > + thermal-sensor@2009400 { > > > > > > > + compatible = "allwinner,sun20i-d1-ths"; > > > > > > > + reg = <0x02009400 0x400>; > > > > > > > + interrupts = <0 90 0>; > > > > > > > + clocks = <&ccu 0>; > > > > > > > + clock-names = "bus"; > > > > > > > + resets = <&ccu 2>; > > > > > > > + nvmem-cells = <&ths_calibration>; > > > > > > > + nvmem-cell-names = "calibration"; > > > > > > > + #thermal-sensor-cells = <0>; > > > > > > > > > > > > > >> Is this calibration required, or optional, for the d1? > > > > > > > > > > > > Calibration data for the D1 is optional as for the H6. > > > > > > (But without it, the sensor data will be inaccurate). > > > > > > > > > > Okay. Modulo the signoff: > > > > > Reviewed-by: Conor Dooley <conor.dooley@xxxxxxxxxxxxx> > > > > > > > > Wait, that's not what I meant to say... Clearly turned my brain off for > > > > a moment. If it is not going to function correctly without the > > > > calibration data, why not make the calibration data required for the > > > > d1's ths? > > > > > > I don't really know why, but the calibration data is optional for > > > other controllers. > > > So I just did it the same way. > > > Here is explanation comment about it from the driver: > > > /* > > > * Even if the external calibration data stored in sid is > > > * not accessible, the THS hardware can still work, although > > > * the data won't be so accurate. > > > * > > > * The default value of calibration register is 0x800 for > > > * every sensor, and the calibration value is usually 0x7xx > > > * or 0x8xx, so they won't be away from the default value > > > * for a lot. > > > * > > > * So here we do not return error if the calibration data is > > > * not available, except the probe needs deferring. > > > */ > > > > Wait, so if there is no calibration data then this thing will just defer > > probing, ad infinitum? Looks like everything other than the a33 has the > > cells in the dts, and the software seems to expect the cells. > > What am I missing? > > Not quite. If we don't have a calibration cell in the dts, then we > just skip the calibration. > We will only get EPROBE_DEFER if we have calibration in the dts. Ah that makes a lot more sense, thanks.
Attachment:
signature.asc
Description: PGP signature