Re: [PATCH 1/3] ASoC: es8316: Increment max value for ALC Capture Target Volume control

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Tue, May 30, 2023 at 03:52:52PM +0300, Cristian Ciocaltea wrote:
> On 5/30/23 14:36, Mark Brown wrote:

> > The other option would be to change the value in the register during
> > probe to one that's in range, that wouldn't stop any existing saved
> > settings from generating errors but would mean there wouldn't be any new
> > ones.  Either approach is probably fine.

> Thanks, I will prepare v2 and keep the current approach.

OK.  Remember that the TLV will need to be updated to show the two
values having identical effect.

Attachment: signature.asc
Description: PGP signature