On Fri, May 05, 2023 at 08:46:06AM +0200, Mårten Lindahl wrote: > 2. Dynamically set the range when a new voltage is set. This way any > voltage from > 0.4V to 3.35V could be set if the DT node has: > regulator-min-microvolt = <400000>; > regulator-max-microvolt = <3350000>; You can probably use one of the linear range mappings with a custom set/get which munges the range selection and voltage selection into a single value.