On Fri, Apr 21, 2023 at 03:37:52PM +0800, Chen-Yu Tsai wrote: > On Thu, Apr 20, 2023 at 5:45 PM AngeloGioacchino Del Regno > <angelogioacchino.delregno@xxxxxxxxxxxxx> wrote: > > > > This platform has three auxiliary NTC thermistors, connected to the > > SoC's ADC pins. Enable the auxadc in order to be able to read the > > ADC values, add a generic-adc-thermal LUT for each and finally assign > > them to the SoC's thermal zones. > > > > Signed-off-by: AngeloGioacchino Del Regno <angelogioacchino.delregno@xxxxxxxxxxxxx> > > --- > > .../boot/dts/mediatek/mt8195-cherry.dtsi | 105 ++++++++++++++++++ > > 1 file changed, 105 insertions(+) > > > > diff --git a/arch/arm64/boot/dts/mediatek/mt8195-cherry.dtsi b/arch/arm64/boot/dts/mediatek/mt8195-cherry.dtsi > > index 8ac80a136c37..0820e9ba3829 100644 > > --- a/arch/arm64/boot/dts/mediatek/mt8195-cherry.dtsi > > +++ b/arch/arm64/boot/dts/mediatek/mt8195-cherry.dtsi > > @@ -114,6 +114,77 @@ ppvar_sys: regulator-ppvar-sys { > > regulator-boot-on; > > }; > > > > + /* Murata NCP03WF104F05RL */ > > + tboard_thermistor1: thermal-sensor-t1 { > > + compatible = "generic-adc-thermal"; > > + #thermal-sensor-cells = <0>; > > + io-channels = <&auxadc 0>; > > + io-channel-names = "sensor-channel"; > > + temperature-lookup-table = < (-10000) 1553 > > + (-5000) 1485 > > + 0 1406 > > + 5000 1317 > > + 10000 1219 > > + 15000 1115 > > + 20000 1007 > > + 25000 900 > > + 30000 796 > > + 35000 697 > > + 40000 605 > > + 45000 523 > > + 50000 449 > > + 55000 384 > > + 60000 327 > > + 65000 279 > > + 70000 237 > > + 75000 202 > > + 80000 172 > > + 85000 147 > > + 90000 125 > > + 95000 107 > > + 100000 92 > > + 105000 79 > > + 110000 68 > > + 115000 59 > > + 120000 51 > > + 125000 44>; > > + }; > > + > > + tboard_thermistor2: thermal-sensor-t2 { > > + compatible = "generic-adc-thermal"; > > + #thermal-sensor-cells = <0>; > > + io-channels = <&auxadc 1>; > > + io-channel-names = "sensor-channel"; > > + temperature-lookup-table = < (-10000) 1553 > > + (-5000) 1485 > > + 0 1406 > > + 5000 1317 > > + 10000 1219 > > + 15000 1115 > > + 20000 1007 > > + 25000 900 > > + 30000 796 > > + 35000 697 > > + 40000 605 > > + 45000 523 > > + 50000 449 > > + 55000 384 > > + 60000 327 > > + 65000 279 > > + 70000 237 > > + 75000 202 > > + 80000 172 > > + 85000 147 > > + 90000 125 > > + 95000 107 > > + 100000 92 > > + 105000 79 > > + 110000 68 > > + 115000 59 > > + 120000 51 > > + 125000 44>; > > + }; > > + > > usb_vbus: regulator-5v0-usb-vbus { > > compatible = "regulator-fixed"; > > regulator-name = "usb-vbus"; > > @@ -260,6 +331,10 @@ &gpu { > > mali-supply = <&mt6315_7_vbuck1>; > > }; > > > > +&auxadc { > > + status = "okay"; > > +}; > > + > > &i2c0 { > > status = "okay"; > > > > @@ -1098,6 +1173,36 @@ mt6315_7_vbuck1: vbuck1 { > > }; > > }; > > > > +&thermal_zones { > > + soc_area_ntc { Not sure if that's what's causing the issue, but the thermal zone name should end with -thermal as per the binding. Also note that it needs to be under 20 characters otherwise it will fail to be registered with -22 like below. (Also, node names shouldn't contain underscore) Thanks, Nícolas > > + polling-delay = <1000>; > > + polling-delay-passive = <250>; > > + thermal-sensors = <&tboard_thermistor1>; > > + > > + trips { > > + trip-crit { > > + temperature = <95000>; > > + hysteresis = <2000>; > > + type = "critical"; > > + }; > > + }; > > + }; > > + > > + pmic_area_ntc { > > + polling-delay = <1000>; > > + polling-delay-passive = <0>; > > + thermal-sensors = <&tboard_thermistor2>; > > + > > + trips { > > + trip-crit { > > + temperature = <95000>; > > + hysteresis = <2000>; > > + type = "critical"; > > + }; > > + }; > > + }; > > I'm still getting: > > thermal_sys: Failed to find 'trips' node > thermal_sys: Failed to find trip points for thermal-sensor-t1 id=0 > generic-adc-thermal thermal-sensor-t1: Thermal zone sensor register failed: -22 > generic-adc-thermal: probe of thermal-sensor-t1 failed with error -22 > thermal_sys: Failed to find 'trips' node > thermal_sys: Failed to find trip points for thermal-sensor-t2 id=0 > generic-adc-thermal thermal-sensor-t2: Thermal zone sensor register failed: -22 > generic-adc-thermal: probe of thermal-sensor-t2 failed with error -22 > thermal_sys: Failed to find 'trips' node > thermal_sys: Failed to find trip points for thermal-sensor-t3 id=0 > generic-adc-thermal thermal-sensor-t3: Thermal zone sensor register failed: -22 > generic-adc-thermal: probe of thermal-sensor-t3 failed with error -22 > > > > > +}; > > + > > &u3phy0 { > > status = "okay"; > > }; > > -- > > 2.40.0 > > > >