On 20/04/2023 22:00, Andreas Klinger wrote: > Honeywell mpr is a pressure sensor series. There are many different models > with different pressure ranges, units and transfer functions. > > The range and transfer function need to be set up in the dt. Therefore new > properties honeywell,pmin-pascal, honeywell,pmax-pascal, > honeywell,transfer-function are introduced. > > Add dt-bindings. > > Signed-off-by: Andreas Klinger <ak@xxxxxxxxxxxxx> > --- > .../iio/pressure/honeywell,mprls0025pa.yaml | 98 +++++++++++++++++++ > 1 file changed, 98 insertions(+) > create mode 100644 Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml > > diff --git a/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml b/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml > new file mode 100644 > index 000000000000..80ab1beac7f6 > --- /dev/null > +++ b/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml > @@ -0,0 +1,98 @@ > +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) > +%YAML 1.2 > +--- > +$id: http://devicetree.org/schemas/iio/pressure/honeywell,mprls0025pa.yaml# > +$schema: http://devicetree.org/meta-schemas/core.yaml# > + > +title: Honeywell mpr series pressure sensor > + > +maintainers: > + - Andreas Klinger <ak@xxxxxxxxxxxxx> > + > +description: | > + Honeywell pressure sensor of model mprls0025pa. > + > + This sensor has an I2C and SPI interface. Only the I2C interface is implemented. > + > + There are many models with different pressure ranges available. The vendor calls them "mpr > + series". All of them have the identical programming model and differ in the pressure range, unit This is a friendly reminder during the review process. It seems my previous comments were not fully addressed. Maybe my feedback got lost between the quotes, maybe you just forgot to apply it. Please go back to the previous discussion and either implement all requested changes or keep discussing them. Thank you. Best regards, Krzysztof