On Thu, Apr 13, 2023 at 08:23:43PM +0200, Sebastian Reichel wrote: > The RK3588 has two reset lines for the combphy. One for the > APB interface and one for the actual PHY. > > Signed-off-by: Sebastian Reichel <sebastian.reichel@xxxxxxxxxxxxx> > --- > .../bindings/phy/phy-rockchip-naneng-combphy.yaml | 7 ++++++- > 1 file changed, 6 insertions(+), 1 deletion(-) > > diff --git a/Documentation/devicetree/bindings/phy/phy-rockchip-naneng-combphy.yaml b/Documentation/devicetree/bindings/phy/phy-rockchip-naneng-combphy.yaml > index 9ae514fa7533..bac1aae07555 100644 > --- a/Documentation/devicetree/bindings/phy/phy-rockchip-naneng-combphy.yaml > +++ b/Documentation/devicetree/bindings/phy/phy-rockchip-naneng-combphy.yaml > @@ -31,8 +31,13 @@ properties: > - const: pipe > > resets: > + minItems: 1 > + maxItems: 2 > + > + reset-names: > items: > - - description: exclusive PHY reset line > + - const: phy > + - const: apb This will fail on any existing users with single entry. You need to add 'minItems: 1' here. It also fails if they didn't use 'phy' as the name, but names should be defined. Rob