On 3/19/23 13:03, Krzysztof Kozlowski wrote:
On 18/03/2023 14:42, Lars-Peter Clausen wrote:
The Xilinx I2C controller device tree bindings documentation documents a
`clock-name` property. There is no such property, the correct property name
is `clock-names` with a `s`. The `s` was accidentally dropped during
conversion from txt to yaml.
Fixes: f86ca4147976 ("dt-bindings: i2c: xiic: Migrate i2c-xiic documentation to YAML")
Signed-off-by: Lars-Peter Clausen <lars@xxxxxxxxxx>
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx>
Reviewed-by: Michal Simek <michal.simek@xxxxxxx>
Thanks,