On Tue, 14 Feb 2023 09:45:54 +0000 Wilken Gottwalt <wilken.gottwalt@xxxxxxxxxx> wrote: Hi, > On Tue, 14 Feb 2023 00:19:29 +0100 > Bastian Germann <bage@xxxxxxxxxx> wrote: > > > The allwinner,sun6i-a31-hwspinlock.yaml binding needs clock-names > > and reset-names set to "ahb" as required by the driver. > > Hmm, this one is a bit odd. If you look into my earlier versions of the > patchset, you may notice, that I actually included these bindings and they > were refused. I think the argumentation was like > "there is only one bus = no need for it". That's interesting, because your driver implementation relies on there being a clock name. And if I chased down devm_clk_get() correctly, there must be a named clock in the DT, otherwise it would fail? I haven't tested this, though, but I guess this is the reason for Bastian's patch. Regarding "one bus clock only": while this is true, I think there is (or was?) also the rationale of using names being more future-proof, so adding clocks (for future hardware revisions) can be done more easily, without breaking compatibility. It's not a big problem, since you probably have a new compatible string in this case anyway, but it also doesn't hurt, and allows to use more generic helpers like devm_clk_get(). > If it gets accepted now, I really like to know why. (It was some trouble > back then to get the documentation properly done and accepted.) IIUC, it simply doesn't work without a clock-names property. Cheers, Andre