When adding support for msm8976 it was thought that msm8956 would reuse the same compat. However checking the vendor kernel revealed that these two platforms use different slope values for calculating the calibration data. Add new compatible for the tsens on msm8956 SoC. Acked-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx> Signed-off-by: Dmitry Baryshkov <dmitry.baryshkov@xxxxxxxxxx> --- Documentation/devicetree/bindings/thermal/qcom-tsens.yaml | 1 + 1 file changed, 1 insertion(+) diff --git a/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml b/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml index 0231f187b097..f3660af0b3bf 100644 --- a/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml +++ b/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml @@ -37,6 +37,7 @@ properties: - description: v1 of TSENS items: - enum: + - qcom,msm8956-tsens - qcom,msm8976-tsens - qcom,qcs404-tsens - const: qcom,tsens-v1 -- 2.35.1