From: Nick Hawkins <nick.hawkins@xxxxxxx> The fans are capable of reporting a fault to the CPLD controller which then reports it to the GXP SoC via PLREGS. This patch enables hwmon to be able to report these failures up to the HOST OS. Signed-off-by: Nick Hawkins <nick.hawkins@xxxxxxx> --- v2: *No change --- Documentation/ABI/testing/sysfs-class-hwmon | 9 +++++++++ 1 file changed, 9 insertions(+) diff --git a/Documentation/ABI/testing/sysfs-class-hwmon b/Documentation/ABI/testing/sysfs-class-hwmon index 7271781a23b2..638f4c6d4ec7 100644 --- a/Documentation/ABI/testing/sysfs-class-hwmon +++ b/Documentation/ABI/testing/sysfs-class-hwmon @@ -276,6 +276,15 @@ Description: RW +What: /sys/class/hwmon/hwmonX/fanY_fault +Description: + Reports if a fan has reported failure. + + - 1: Failed + - 0: Ok + + RO + What: /sys/class/hwmon/hwmonX/pwmY Description: Pulse width modulation fan control. -- 2.17.1