Hello Fabio, Am Montag, dem 21.11.2022 um 13:29 -0300 schrieb Fabio Estevam: > From: Fabio Estevam <festevam@xxxxxxx> > > 'regulator-compatible' is not a valid property according to > nxp,pca9450-regulator.yaml and causes the following warning: > > DTC_CHK arch/arm64/boot/dts/freescale/imx8mp-dhcom-pdk2.dtb > ... > pmic@25: regulators:LDO1: Unevaluated properties are not allowed > ('regulator-compatible' was unexpected) > > Remove the invalid 'regulator-compatible' property. Reviewed-by: Teresa Remmet <t.remmet@xxxxxxxxx> thank you for the patch. I have noticed this already, too.. But the patch stack that includes this, still waits for getting finished up. So you where quicker. Regards, Teresa > > Cc: Teresa Remmet <t.remmet@xxxxxxxxx> > Fixes: 88f7f6bcca37 ("arm64: dts: freescale: Add support for > phyBOARD-Pollux-i.MX8MP") > Signed-off-by: Fabio Estevam <festevam@xxxxxxx> > --- > arch/arm64/boot/dts/freescale/imx8mp-phycore-som.dtsi | 10 ------- > --- > 1 file changed, 10 deletions(-) > > diff --git a/arch/arm64/boot/dts/freescale/imx8mp-phycore-som.dtsi > b/arch/arm64/boot/dts/freescale/imx8mp-phycore-som.dtsi > index 79b290a002c1..ecc4bce6db97 100644 > --- a/arch/arm64/boot/dts/freescale/imx8mp-phycore-som.dtsi > +++ b/arch/arm64/boot/dts/freescale/imx8mp-phycore-som.dtsi > @@ -99,7 +99,6 @@ pmic: pmic@25 { > > regulators { > buck1: BUCK1 { > - regulator-compatible = "BUCK1"; > regulator-min-microvolt = <600000>; > regulator-max-microvolt = <2187500>; > regulator-boot-on; > @@ -108,7 +107,6 @@ buck1: BUCK1 { > }; > > buck2: BUCK2 { > - regulator-compatible = "BUCK2"; > regulator-min-microvolt = <600000>; > regulator-max-microvolt = <2187500>; > regulator-boot-on; > @@ -119,7 +117,6 @@ buck2: BUCK2 { > }; > > buck4: BUCK4 { > - regulator-compatible = "BUCK4"; > regulator-min-microvolt = <600000>; > regulator-max-microvolt = <3400000>; > regulator-boot-on; > @@ -127,7 +124,6 @@ buck4: BUCK4 { > }; > > buck5: BUCK5 { > - regulator-compatible = "BUCK5"; > regulator-min-microvolt = <600000>; > regulator-max-microvolt = <3400000>; > regulator-boot-on; > @@ -135,7 +131,6 @@ buck5: BUCK5 { > }; > > buck6: BUCK6 { > - regulator-compatible = "BUCK6"; > regulator-min-microvolt = <600000>; > regulator-max-microvolt = <3400000>; > regulator-boot-on; > @@ -143,7 +138,6 @@ buck6: BUCK6 { > }; > > ldo1: LDO1 { > - regulator-compatible = "LDO1"; > regulator-min-microvolt = <1600000>; > regulator-max-microvolt = <3300000>; > regulator-boot-on; > @@ -151,7 +145,6 @@ ldo1: LDO1 { > }; > > ldo2: LDO2 { > - regulator-compatible = "LDO2"; > regulator-min-microvolt = <800000>; > regulator-max-microvolt = <1150000>; > regulator-boot-on; > @@ -159,7 +152,6 @@ ldo2: LDO2 { > }; > > ldo3: LDO3 { > - regulator-compatible = "LDO3"; > regulator-min-microvolt = <800000>; > regulator-max-microvolt = <3300000>; > regulator-boot-on; > @@ -167,13 +159,11 @@ ldo3: LDO3 { > }; > > ldo4: LDO4 { > - regulator-compatible = "LDO4"; > regulator-min-microvolt = <800000>; > regulator-max-microvolt = <3300000>; > }; > > ldo5: LDO5 { > - regulator-compatible = "LDO5"; > regulator-min-microvolt = <1800000>; > regulator-max-microvolt = <3300000>; > regulator-boot-on; -- PHYTEC Messtechnik GmbH | Barcelona-Allee 1 | 55129 Mainz, Germany Geschäftsführer: Dipl.-Ing. Michael Mitezki, Dipl.-Ing. Bodo Huber | Handelsregister Mainz HRB 4656 | Finanzamt Mainz | St.Nr. 266500608, DE 149059855