Re: [PATCH 2/3] phy: qcom-qmp-usb: drop sc8280xp reference-clock source

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 11/11/2022 12:38, Johan Hovold wrote:
The source clock for the reference clock is not used by the PHY directly
and should not be described by the devicetree (instead this relationship
should be modelled in the clock driver).

Drop the driver management of the reference-clock source for SC8280XP.

Once the other clock drivers have been updated, the corresponding change
can be done also for the other QMP v4 platforms.

It would be nice to also understand, how does this apply to the sm8250's usb+dp PHY, which has ref_clk_src, but no ref clock.

Bjorn, any comments?

Other than this question:

Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@xxxxxxxxxx>


--
With best wishes
Dmitry