On Wed, Sep 14, 2022 at 5:19 PM Arınç ÜNAL <arinc.unal@xxxxxxxxxx> wrote: > > On 14.09.2022 18:14, Rob Herring wrote: > > On Wed, Sep 14, 2022 at 11:54:45AM +0300, Arınç ÜNAL wrote: > >> Add syscon as a constant string on the compatible property as it's required > >> for the SoC to work. Update the example accordingly. > > > > It's not required. It's required to automagically create a regmap. That > > can be done yourself as well. The downside to adding 'syscon' is it > > requires a DT update. Maybe that's fine for this platform? I don't know. > > My GB-PC2 won't boot without syscon on mt7621.dtsi. This string was > always there on the memory controller node on mt7621.dtsi. The string was introduced because the mt7621 clock driver needs to read some registers creating a regmap from the syscon. The bindings were added before the clock driver was properly mainlined and at first the clock driver was using ralink architecture dependent operations rt_memc_* defined in 'arch/mips/include/asm/mach-ralink/ralink_regs.h'. I forgot to update the mem controller binding when memc became a syscon so I think this patch is correct. I also think the sample should use 'syscon' in the node name instead of memory-controller. Best regards, Sergio Paracuellos > > Arınç