Hi, On Sat, Oct 11, 2014 at 12:20:04PM +0200, Johan Hovold wrote: > On Fri, Oct 10, 2014 at 01:02:56PM -0500, Felipe Balbi wrote: > > On Fri, Oct 10, 2014 at 01:00:54PM -0500, Felipe Balbi wrote: > > > On Thu, Oct 09, 2014 at 09:06:29PM +0200, Johan Hovold wrote: > > > > Some legacy RTC IP revisions has a power-up reset flag in the status > > > > register that later revisions lack. > > > > > > > > As this flag is always read back as set on later revisions (or is > > > > overloaded with a different flag), make sure to only clear the flag and > > > > print the info message on legacy platforms. > > > > > > > > Signed-off-by: Johan Hovold <johan@xxxxxxxxxx> > > > > > > Reviewed-by: Felipe Balbi <balbi@xxxxxx> > > > > oh, btw. This should be done for DT probes too. > > What do you mean? This is for DT probes (of "ti,da830-rtc" and > "ti,am3352-rtc"). DT probing of legacy RTC IPs is currently not > supported. > > Are you suggesting I should add a new compatible string for that? it seemed to me that you're only passing the new flag through platform_device_id table, not DT table. Did I miss something ? -- balbi