From: Andrea Merello <andrea.merello@xxxxxx> Introduce ABI documentation for new IIO modifiers used for reporting "linear acceleration" measures. Signed-off-by: Andrea Merello <andrea.merello@xxxxxx> Reviewed-by: Andy Shevchenko <andy.shevchenko@xxxxxxxxx> --- Documentation/ABI/testing/sysfs-bus-iio | 9 +++++++++ 1 file changed, 9 insertions(+) diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio index 80e8a38d1ee2..cc1fe672580f 100644 --- a/Documentation/ABI/testing/sysfs-bus-iio +++ b/Documentation/ABI/testing/sysfs-bus-iio @@ -260,6 +260,15 @@ Description: Has all of the equivalent parameters as per voltageY. Units after application of scale and offset are m/s^2. +What: /sys/bus/iio/devices/iio:deviceX/in_accel_linear_x_raw +What: /sys/bus/iio/devices/iio:deviceX/in_accel_linear_y_raw +What: /sys/bus/iio/devices/iio:deviceX/in_accel_linear_z_raw +KernelVersion: 6.1 +Contact: linux-iio@xxxxxxxxxxxxxxx +Description: + As per in_accel_X_raw attributes, but minus the + acceleration due to gravity. + What: /sys/bus/iio/devices/iio:deviceX/in_gravity_x_raw What: /sys/bus/iio/devices/iio:deviceX/in_gravity_y_raw What: /sys/bus/iio/devices/iio:deviceX/in_gravity_z_raw -- 2.17.1