If we are not in PWM mode, then the output is technically a 50% output based on a single timer instead of the high-low based on the two counters. Add a check for the PWM mode in dwc_pwm_get_state() and if DWC_TIM_CTRL_PWM is not set, then return a 50% cycle. This may only be an issue on initialisation, as the rest of the code currently assumes we're always going to have the extended PWM mode using two counters. Signed-off-by: Ben Dooks <ben.dooks@xxxxxxxxxx> --- drivers/pwm/pwm-dwc.c | 34 +++++++++++++++++++++++----------- 1 file changed, 23 insertions(+), 11 deletions(-) diff --git a/drivers/pwm/pwm-dwc.c b/drivers/pwm/pwm-dwc.c index da325133d297..f3723c4d1e59 100644 --- a/drivers/pwm/pwm-dwc.c +++ b/drivers/pwm/pwm-dwc.c @@ -171,23 +171,35 @@ static void dwc_pwm_get_state(struct pwm_chip *chip, struct pwm_device *pwm, { struct dwc_pwm *dwc = to_dwc_pwm(chip); u64 duty, period; + u32 ctrl, ld, ld2; pm_runtime_get_sync(chip->dev); - state->enabled = !!(dwc_pwm_readl(dwc, - DWC_TIM_CTRL(pwm->hwpwm)) & DWC_TIM_CTRL_EN); + ctrl = dwc_pwm_readl(dwc, DWC_TIM_CTRL(pwm->hwpwm)); + ld = dwc_pwm_readl(dwc, DWC_TIM_LD_CNT(pwm->hwpwm)); + ld2 = dwc_pwm_readl(dwc, DWC_TIM_LD_CNT2(pwm->hwpwm)); - duty = dwc_pwm_readl(dwc, DWC_TIM_LD_CNT(pwm->hwpwm)); - duty += 1; - duty *= dwc->clk_ns; - state->duty_cycle = duty; + state->enabled = !!(ctrl & DWC_TIM_CTRL_EN); - period = dwc_pwm_readl(dwc, DWC_TIM_LD_CNT2(pwm->hwpwm)); - period += 1; - period *= dwc->clk_ns; - period += duty; - state->period = period; + /* If we're not in PWM, technically the output is a 50-50 + * based on the timer load-count only. + */ + if (ctrl & DWC_TIM_CTRL_PWM) { + duty = ld; + duty += 1; + duty *= dwc->clk_ns; + + period = ld2; + period += 1; + period *= dwc->clk_ns; + period += duty; + } else { + duty = (ld + 1) * dwc->clk_ns; + period = duty * 2; + } + state->period = period; + state->duty_cycle = duty; state->polarity = PWM_POLARITY_INVERSED; pm_runtime_put_sync(chip->dev); -- 2.35.1