On Mon, Jul 25, 2022 at 11:32:16AM +0200, Andy Shevchenko wrote: > On Thu, Jul 21, 2022 at 11:32 AM Marcus Folkesson > <marcus.folkesson@xxxxxxxxx> wrote: > > > > 74hc4094 and 75hc4094 works similar to 74x164 but has an additional > > storage latch associated with each stage for strobing data from the > > serial input to parallell buffer tri-state output. > > parallel > > > Add support for an optional strobe pin. > > Sorry for my absence of understanding, but why? > SPI has MOSI, CLK, CS, where the last one is exactly for that. No? You're right, I didn't think of that CS could be used for this. The additional compatible strings is then superfluous, so I will skip those. > > > -- > With Best Regards, > Andy Shevchenko Best regards Marcus Folkesson