Am Mittwoch, dem 20.07.2022 um 06:34 +0200 schrieb Martin Kepplinger: > For boards that use power-domains' power-supplies that need interrupts > to work (like regulator over i2c), set GENPD_FLAG_IRQ_ON. > This will tell genpd to adjust accordingly. Currently it "only" sets the > correct suspend/resume callbacks. > > This fixes suspend/resume on imx8mq-librem5 boards (tested) and > imx8mq-evk (by looking at dts) and possibly more. > > Signed-off-by: Martin Kepplinger <martin.kepplinger@xxxxxxx> > --- > drivers/soc/imx/gpcv2.c | 9 +++++++++ > 1 file changed, 9 insertions(+) > > diff --git a/drivers/soc/imx/gpcv2.c b/drivers/soc/imx/gpcv2.c > index 85aa86e1338a..46d2ead2352b 100644 > --- a/drivers/soc/imx/gpcv2.c > +++ b/drivers/soc/imx/gpcv2.c > @@ -1303,6 +1303,7 @@ static const struct imx_pgc_domain_data imx8mn_pgc_domain_data = { > static int imx_pgc_domain_probe(struct platform_device *pdev) > { > struct imx_pgc_domain *domain = pdev->dev.platform_data; > + struct device_node *dn; > int ret; > > domain->dev = &pdev->dev; > @@ -1333,6 +1334,14 @@ static int imx_pgc_domain_probe(struct platform_device *pdev) > regmap_update_bits(domain->regmap, domain->regs->map, > domain->bits.map, domain->bits.map); > > + dn = of_parse_phandle(domain->dev->of_node, "power-supply", 0); > + if (dn) { > + while ((dn = of_get_next_parent(dn))) { > + if (of_get_property(dn, "interrupts", NULL)) > + domain->genpd.flags |= GENPD_FLAG_IRQ_ON; > + } > + } > + While I understand the intention, I think the DT walking is overkill. I believe that there are no cases where we have a external regulator attached to the PD and the devices in the domain needing noirq support. I think it's sufficient to simply set the IRQ_ON flag based on presence of the power-supply property on the domain DT node. Regards, Lucas > ret = pm_genpd_init(&domain->genpd, NULL, true); > if (ret) { > dev_err(domain->dev, "Failed to init power domain\n");