IPQ6018 and IPQ8074 require #clock-cells to be set to 1 as their APSS clock driver provides multiple clock outputs. So allow setting 1 as #clock-cells and check that its set to 1 for IPQ6018 and IPQ8074, check others for 0 as its currently. Signed-off-by: Robert Marko <robimarko@xxxxxxxxx> Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx> --- Changes in v3: * Drop not needed blank line Changes in v2: * Correct subject name --- .../bindings/mailbox/qcom,apcs-kpss-global.yaml | 17 ++++++++++++++++- 1 file changed, 16 insertions(+), 1 deletion(-) diff --git a/Documentation/devicetree/bindings/mailbox/qcom,apcs-kpss-global.yaml b/Documentation/devicetree/bindings/mailbox/qcom,apcs-kpss-global.yaml index 3b5ba7ecc19d..95ecb84e3278 100644 --- a/Documentation/devicetree/bindings/mailbox/qcom,apcs-kpss-global.yaml +++ b/Documentation/devicetree/bindings/mailbox/qcom,apcs-kpss-global.yaml @@ -50,7 +50,7 @@ properties: const: 1 '#clock-cells': - const: 0 + enum: [0, 1] clock-names: minItems: 2 @@ -96,6 +96,21 @@ allOf: properties: clocks: maxItems: 3 + - if: + properties: + compatible: + enum: + - qcom,ipq6018-apcs-apps-global + - qcom,ipq8074-apcs-apps-global + then: + properties: + '#clock-cells': + const: 1 + else: + properties: + '#clock-cells': + const: 0 + examples: # Example apcs with msm8996 -- 2.36.1