On Wed, Jun 29, 2022 at 4:30 PM Aidan MacDonald <aidanmacdonald.0x0@xxxxxxxxx> wrote: > > Add a "has_fg" flag to indicate that the chip has a fuel gauge. > Report battery full status on chips with no fuel gauge using the > battery voltage. Reviewed-by: Andy Shevchenko <andy.shevchenko@xxxxxxxxx> > Acked-by: Sebastian Reichel <sebastian.reichel@xxxxxxxxxxxxx> > Signed-off-by: Aidan MacDonald <aidanmacdonald.0x0@xxxxxxxxx> > --- > drivers/power/supply/axp20x_battery.c | 34 ++++++++++++++++++++++++++- > 1 file changed, 33 insertions(+), 1 deletion(-) > > diff --git a/drivers/power/supply/axp20x_battery.c b/drivers/power/supply/axp20x_battery.c > index 401779d84d2b..574c1d001556 100644 > --- a/drivers/power/supply/axp20x_battery.c > +++ b/drivers/power/supply/axp20x_battery.c > @@ -69,6 +69,7 @@ struct axp_data { > * must have AXP20X_CHRG_CTRL1_TGT_CURR+1 elements. > */ > const int *ccc_table; > + bool has_fg; > bool has_fg_valid; > int (*get_max_voltage)(struct axp20x_batt_ps *batt, int *val); > int (*set_max_voltage)(struct axp20x_batt_ps *batt, int val); > @@ -197,7 +198,7 @@ static int axp20x_battery_get_prop(struct power_supply *psy, > union power_supply_propval *val) > { > struct axp20x_batt_ps *axp20x_batt = power_supply_get_drvdata(psy); > - int ret = 0, reg, val1; > + int ret = 0, reg, val1, val2; > > switch (psp) { > case POWER_SUPPLY_PROP_PRESENT: > @@ -231,6 +232,34 @@ static int axp20x_battery_get_prop(struct power_supply *psy, > return 0; > } > > + /* > + * If the chip does not have a fuel gauge, we check battery full status > + * using voltage instead. > + */ > + if (!axp20x_batt->data->has_fg) { > + ret = axp20x_batt->data->get_max_voltage(axp20x_batt, &val1); > + if (ret) > + return ret; > + > + ret = iio_read_channel_processed(axp20x_batt->batt_v, &val2); > + if (ret) > + return ret; > + > + /* IIO subsystem reports voltage in mV but we need uV */ > + val2 *= 1000; > + > + /* > + * According to the AXP192 datasheet, charging will restart if > + * the battery voltage drops below V_rch = V_tgt - 0.1 V, so we > + * report the battery is full if its voltage is at least V_rch. > + */ > + if (val2 >= val1 - 100000) > + val->intval = POWER_SUPPLY_STATUS_FULL; > + else > + val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING; > + break; > + } > + > ret = regmap_read(axp20x_batt->regmap, AXP20X_FG_RES, &val1); > if (ret) > return ret; > @@ -552,6 +581,7 @@ static const struct power_supply_desc axp20x_batt_ps_desc = { > static const struct axp_data axp209_data = { > .ccc_scale = 100000, > .ccc_offset = 300000, > + .has_fg = true, > .get_max_voltage = axp20x_battery_get_max_voltage, > .set_max_voltage = axp20x_battery_set_max_voltage, > }; > @@ -559,6 +589,7 @@ static const struct axp_data axp209_data = { > static const struct axp_data axp221_data = { > .ccc_scale = 150000, > .ccc_offset = 300000, > + .has_fg = true, > .has_fg_valid = true, > .get_max_voltage = axp22x_battery_get_max_voltage, > .set_max_voltage = axp22x_battery_set_max_voltage, > @@ -567,6 +598,7 @@ static const struct axp_data axp221_data = { > static const struct axp_data axp813_data = { > .ccc_scale = 200000, > .ccc_offset = 200000, > + .has_fg = true, > .has_fg_valid = true, > .get_max_voltage = axp813_battery_get_max_voltage, > .set_max_voltage = axp20x_battery_set_max_voltage, > -- > 2.35.1 > -- With Best Regards, Andy Shevchenko