On 27/06/2022 16:35, Krzysztof Kozlowski wrote:
On 27/06/2022 11:32, Quan Nguyen wrote:
+
+ ltc2497_reg: ltc2497_regulator {
No underscores in node name, no specific names (Devicetree spec requires
generic), so ltc2497 has to go. You could add some more specific
prefix/suffix to describe the function.
This is to monitor peripheral voltage so it would be updated to:
But it is a regulator, not a voltage monitor, so the node name could be:
regulator-0
regulator-voltage-mon
voltage-mon-regulator
Yes, I think I would pick the voltage-mon-regulator:
voltage_mon_reg: voltage-mon-monitor {
voltage_monitor: voltage-monitor {
+ compatible = "regulator-fixed";
+ regulator-name = "ltc2497_reg";
+ regulator-min-microvolt = <3300000>;
+ regulator-max-microvolt = <3300000>;
+ regulator-always-on;
+ };
+
Thanks a lot for the quick suggestion.
- Quan