On Tue, May 31, 2022 at 02:49:55PM +0200, Fabien Parent wrote: > + properties: > + regulator-name: > + pattern: "^v(core|modem|pa|proc|s1)$" This is a standard property which you shouldn't need to describe and should not be imposing any constraints on, the property is there to provide a system relevant name to the supply provided by the regulator to aid diagnostics and association with schematics.