Il 28/04/22 13:56, Rex-BC Chen ha scritto:
The bank offsets are not serial for all reset registers. For example, there are five infra reset banks for MT8192: 0x120, 0x130, 0x140, 0x150 and 0x730. To support this, - Change reg_ofs to rst_bank_ofs which is a pointer to base offsets of the reset register. - Add a new define RST_NR_PER_BANK to define reset number for each reset bank. Signed-off-by: Rex-BC Chen <rex-bc.chen@xxxxxxxxxxxx>
Reviewed-by: AngeloGioacchino Del Regno <angelogioacchino.delregno@xxxxxxxxxxxxx>