On Wed, Apr 13, 2022 at 07:23:46PM -0500, Samuel Holland wrote: > The R329 and D1 SoCs each contain an LRADC with a programming interface > compatible to earlier LRADCs. However, the LRADC now has its own clock > gate and reset line, instead of being always active. > > To support this, add clock/reset properties to the binding, and require > them for the variant in the new SoCs. > > Acked-by: Maxime Ripard <maxime@xxxxxxxxxx> > Reviewed-by: Rob Herring <robh@xxxxxxxxxx> > Signed-off-by: Samuel Holland <samuel@xxxxxxxxxxxx> Applied, thank you. -- Dmitry