On 11/01/2022 at 14:23, Tudor Ambarus wrote:
PMERRLOC resource size was set to 0x100, which resulted in HSMC_ERRLOCx
register being truncated to offset x = 21, causing error correction to
fail if more than 22 bit errors and if 24 or 32 bit error correction
was supported.
Fixes: d9c41bf30cf8 ("ARM: dts: at91: Declare EBI/NAND controllers")
Signed-off-by: Tudor Ambarus <tudor.ambarus@xxxxxxxxxxxxx>
Cc: <stable@xxxxxxxxxxxxxxx> # 4.13.x
Acked-by: Nicolas Ferre <nicolas.ferre@xxxxxxxxxxxxx>
Even if it's a fix, as we have this bug for a long time and that we are
already at rc5 of the stabilization phase, I take it in at91-dt branch
for 5.18 and not in another "fixes" batch.
Best regards,
Nicolas
---
v2:
- update commit description
- Cc stable@xxxxxxxxxxxxxxx
arch/arm/boot/dts/sama5d2.dtsi | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/arch/arm/boot/dts/sama5d2.dtsi b/arch/arm/boot/dts/sama5d2.dtsi
index 09c741e8ecb8..c700c3b19e4c 100644
--- a/arch/arm/boot/dts/sama5d2.dtsi
+++ b/arch/arm/boot/dts/sama5d2.dtsi
@@ -415,7 +415,7 @@ hsmc: hsmc@f8014000 {
pmecc: ecc-engine@f8014070 {
compatible = "atmel,sama5d2-pmecc";
reg = <0xf8014070 0x490>,
- <0xf8014500 0x100>;
+ <0xf8014500 0x200>;
};
};
--
Nicolas Ferre