Re: [PATCH v2 0/2] Enable i.MX7 SOLO temperature sensor

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 24-01-22, 09:28, Francesco Dolcini wrote:
> To be able to read the T junction on i.MX CPU the imx-cpufreq-dt needs to be
> loaded, however this is currently not the case for i.MX7S given that it does
> have only one operating frequency.
> 
> Add "fsl,imx7s" to cpufreq-dt-platdev blocklist and a single frequency
> operating point to the CPU.
> 
> With that it is now possible to correctly read the CPU T junction.
> 
> Tested on Toradex Colibri iMX7S
> 
> [    6.232577] imx-cpufreq-dt imx-cpufreq-dt: cpu speed grade 0 mkt segment 1 supported-hw 0x1 0x2
> ...
> [    6.880624] imx_thermal 30360000.anatop:tempmon: Extended Commercial CPU temperature grade - max:105C critical:100C passive:95C
> 
> root@colibri-imx7-02983025:~# cat /sys/class/thermal/thermal_zone0/temp 
> 38000
> 
> v2:
>  - removed empty new line
>  - rebased and tested on v5.17-rc1

Applied. Thanks.

-- 
viresh