On Mon, Jan 24, 2022 at 04:27:35PM -0800, David Collins wrote: > Name based SCMI regulator specification helps ensure that an SCMI > agent doesn't need to be aware of the numbering scheme used for What is a "SCMI agent" in this context? This is changing how the DT bindings are specified, at some point things are going to need to be hard coded. > + regulator-name: true > + > + anyOf: > + - required: > + - reg > + - required: > + - regulator-name This is abusing the existing regulator-name property which is there to allow a human readable descriptive string to be attached to a regulator. It should have no effect other than being included in diagnostic output.