On Sun, Jan 16, 2022 at 22:15, Tobias Waldekranz <tobias@xxxxxxxxxxxxxx> wrote: > Once an MDIO read transaction is initiated, we must read back the data > register within 16 MDC cycles after the transaction completes. Outside > of this window, reads may return corrupt data. > > Therefore, disable local interrupts in the critical section, to > maximize the probability that we can satisfy this requirement. > > Signed-off-by: Tobias Waldekranz <tobias@xxxxxxxxxxxxxx> Fixes: d55ad2967d89 ("powerpc/mpc85xx: Create dts components for the FSL QorIQ DPAA FMan")