[PATCH v1 0/2] Enable i.MX7 SOLO temperature sensor

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



To be able to read the T junction on i.MX CPU the imx-cpufreq-dt needs to be
loaded, however this is currently not the case for i.MX7S given that it does
have only one operating frequency.

Add "fsl,imx7s" to cpufreq-dt-platdev blocklist and a single frequency
operating point to the CPU.

With that it is now possible to correctly read the CPU T junction.

Tested on Toradex Colibri iMX7S

[    6.232577] imx-cpufreq-dt imx-cpufreq-dt: cpu speed grade 0 mkt segment 1 supported-hw 0x1 0x2
...
[    6.880624] imx_thermal 30360000.anatop:tempmon: Extended Commercial CPU temperature grade - max:105C critical:100C passive:95C

root@colibri-imx7-02983025:~# cat /sys/class/thermal/thermal_zone0/temp 
38000


Denys Drozdov (1):
  ARM: dts: imx7s: Define operating points table for cpufreq

Stefan Agner (1):
  cpufreq: Add i.MX7S to cpufreq-dt-platdev blocklist

 arch/arm/boot/dts/imx7s.dtsi         | 16 ++++++++++++++++
 drivers/cpufreq/cpufreq-dt-platdev.c |  2 ++
 2 files changed, 18 insertions(+)

-- 
2.25.1




[Index of Archives]     [Device Tree Compilter]     [Device Tree Spec]     [Linux Driver Backports]     [Video for Linux]     [Linux USB Devel]     [Linux PCI Devel]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [XFree86]     [Yosemite Backpacking]


  Powered by Linux